[ Basic Info | References | User Guide ]
Basic Information on uvindex
Task: uvindex
Purpose: Scan a uvdata file, and note when uvvariables change.
Categories: uv analysis, checking
UVINDEX is a Miriad program which scans a uvdata file.
Changes in source name, pointing center, number of wideband
and spectral line channels, the observing frequency, and
polarization are listed in the output.
Key: vis
The input visibility file. No default.
Key: interval
Reissue source information if no data for this period in minutes.
The default is 60 minutes.
Key: refant
Reference antenna for variables that are antenna based
(e.g. dazim, delev).
Use 0 to skip accumulating this type of data .
Default: 1
Key: log
The output log file. Default is the terminal.
Key: options
Extra processing options. Currently there is but one of these:
mosaic Do not generate messages for different pointings
of a mosaic.
smacorr Do mapping SMA correlator configuration to Miriad
frequency configuration. Only works for the
Miriad visdata set imported directly from smalod.